Quantcast
Channel: Storage - Wiki
Viewing all articles
Browse latest Browse all 486

XC730xd Series Support Matrix

$
0
0
Current Revision posted to Storage - Wiki by LScheuplein on 3/2/2017 8:11:51 PM

IntroductionManagement softwareContacting Dell EMC
ComponentsHypervisor OSsQuick Resource Locator
Physical disk drivesTechnical specifications 
HBAsDocumentation matrix 
NetworkingDell EMC documentation
Hardware managementNutanix documentation

What's New!

03/02/2017 Added direct links to firmware.

02/01/2017 Updated list of supported BIOS and iDRAC versions.

Introduction  (Back to top)

This document provides information about the supported software, firmware, and hardware versions and technical specifications for the Dell EMC XC730xd Web-Scale Hyper-converged Appliance.

NOTE: This Support Matrix contains the latest compatibility and interoperability information. If you observe inconsistencies between this information and other documentation or references, this document supersedes all other documentation.

Supported hardware, firmware and software  (Back to top)

This chapter provides information about supported software, firmware, and hardware versions for the Dell EMC XC730xd Web-Scale Hyper-converged Appliance.

Supported components

This section provides information about components supported by your hardware.

Supported Components
Componentv3 Versionv4 Version
CPUsE5-2620 v3E52603 v4
 E5-2630 v3E52608L v4
 E5-2643 v3E52609 v4
 E5-2650 v3E52618L v4
 E5-2660 v3E52620 v4
 E5-2680 v3E52623 v4
 E5-2690 v3E52628L v4
 E5-2695 v3E52630L v4
 E5-2697 v3E52630 v4
 E5-2698 v3E52637 v4
  E52640 v4
  E52643 v4
  E52648L v4
  E52650L v4
  E52650 v4
  E52658 v4
  E52660 v4
  E52667 v4
  E52680 v4
  E52683 v4
  E52690 v4
  E52695 v4
  E52603 v4
BIOS
 1.2.10 and later2.0.2 or later
iDRAC support
 2.02.02.01 or later2.30.30.30 or later

Validated BIOS and iDRAC versions

Each row in the table here represents the validated BIOS and iDRAC version pair.

Validated BIOS and iDRAC versions
BIOSiDRAC
1.3.62.02.02.02
1.3.62.20.20.20
1.5.42.20.20.20
2.0.12.30.30.30
2.0.22.40.40.03
2.1.62.40.40.03
2.2.42.40.40.40
2.3.42.40.40.40

Supported physical disk drives (Back to top)

This section provides information about disks drives supported by your hardware.

Supported Physical Disk Drives
Form FactorCapacityTypeVendorChassis
2.5"1 TBNL-SAS HDDDell EMC Supported–24
2.5"1.2 TBSAS HDDDell EMC Supported–24
2.5"2 TBNL-SASDell EMC Supported–24
2.5"1 TBSED HDDDell EMC Supported–24
2.5"1.2 TBSED HDDDell EMC Supported–24
 2 TBSED HDDDell EMC Supported–24
2.5"200 GBSATA SSDIntel–24, –12
2.5"400 GBSATA SSDIntel–24, –12
2.5"800 GBSATA SSDIntel–24, –12
2.5"1600 GBSATA SSDIntel-24, -12
2.5"200 GBSAS SSDHGST–24, –12
2.5"400 GBSAS SSDHGST–24, –12
2.5"800 GBSAS SSDHGST–24, –12
2.5"400 GBSAS SED SSDHGST–24, –12
2.5"800 GBSAS SED SSDHGST–24, –12
2.5"1600 GBSAS SED SSDHGST–24, –12
3.5"2 TBNL-SAS HDDDell EMC Supported-12
3.5"4 TBNL-SAS HDDDell EMC Supported-12
3.5"6 TBNL-SAS HDDDell EMC Supported-12
3.5"8 TBNL-SAS HDDDell EMC Supported-12
3.5"10 TBNL-SAS HDDDell EMC Supported-12
3.5"4 TBSED HDDDell EMC Supported-12
3.5"6 TBSED HDDDell EMC Supported-12
3.5"480 GBSATA SSDSamsung-12
3.5"960 GBSATA SSDSamsung-12
3.5"1920 GBSATA SSDSamsung-12
3.5"3840 GBSAS SSDToshiba-12

Supported HBAs (Back to top)

This section provides information about Host Bus Adapters (HBA) supported by your hardware.

Supported HBAs
NameForm factor/SlotMinimum firmware version
H730Mini or integrated slot25.3.0-0016
HBA330Mini or integrated slot

9.17.20.07

NOTE: This version is supported on NOS 4.1.3.x.

Supported networking (Back to top)

This section provides information about networking supported by your hardware and supported NICs.

Intel branded Network Daughter Cards (NDC) and Network Interface Cards (NIC) specify the use of only Intel branded SFP+ optical modules for use with optical cables. When ordering a system with optics, the appropriate Intel branded SFP+ optical modules are included with your order. If you already have SFP+ optical modules, ensure they are the Intel branded modules before inserting into the NDC or NIC. Twinax cables are also the supported network cables for Intel NDC and NIC.

CAUTION: Using any brand of SFP+ module other than Intel during deployment disables the 10 GbE ports. Call Dell EMC Support to recover port functionality.

WARNING: Hot-plugging an unsupported SFP+ module causes ESXi host to fail with purple diagnostic screen. Call Dell EMC Support to recover from this situation.

 

Supported NDCs
NameFirmware versionMinimum firmware version
Intel X520 Dual 1G + Dual 10 G SFP+16.0.24
  • Intel randed SFP+ modules only (10 GbE)
  • Twinax Cable (10 GbE)
  • Standard Category 6 Ethernet (1 GbE)
Intel X540 Dual 1 G + Dual 10 G Base16.0.24Standard Category 6 Ethernet (up to 10 GbE)

 

Supported NICs
NameFrom factor or SlotMinimum firmware versionSupported cables
Intel X520 Dual 10 G SFP+Low profile or full height/any slot16.0.24

Intel branded SFP+ modules only (10 GbE)

Twinax Cable (10 GbE)

Intel X540 Dual 10 G BaseTLow profile or full height/any slot16.0.24Standard Category 6 Ethernet (up to 10 GbE)

Supported hardware management solutions   (Back to top)

This section provides information about hardware management solutions that are supported by your hardware.

Supported hardware management solutions
NameMinimum firmware version
Dell OpenManage Essentials2.0
Dell Nautilus Firmware Update UtilityA13

Supported management software   (Back to top)

This section provides information about components supported by your hardware.

Supported management software
NameMinimum version
Nutanix Operating System (NOS)

4.1.1.1 (Haswell)

4.5.1.2 (Broadwell)

Supported hypervisor OS   (Back to top)

This section provides information about the hypervisor Operating Systems (OS) supported by your hardware.

Supported hypervisor OS
NameMinimum firmware version
VMware
  • ESXi 5.5, update 2 (Haswell)
  • ESXi 6.0 (Haswell)
  • ESXi 5.5, update 3 (Broadwell)
  • ESXi 6.0, update 1 (Broadwell)
Windows Server

Windows Server 2012 R2 Standard Edition

Windows Server 2012 R2 Datacenter Edition

Acropolis Hypervisor (AHV)

Nutanix 20150616 (Haswell)

Nutanix 20160921 (Broadwell)

Technical specifications   (Back to top)

This chapter provides technical specifications for Dell EMC XC730xd Web-Scale Hyperconverged Appliance.

PhysicalPowerConnectors
Processor MemoryVideo
Expansion busHardriveEnvironmental

 

Physical specifications

This section provides expansion physical specifications for storage, including height, width, depth, maximum configuration weight and empty weight.

Physical specifications
PhysicalSpecification
Height8.73 cm (3.44 inch)
Width48.2 cm (18.98 inch)
Depth75.58 cm (29.75 inch)
Weight (Maximum)

30.4 kg (67.02 lb) (2.5 inch hard drive systems)

36.5 kg (80.47 lb) (3.5 inch hard drive systems)

Weight (Empty)

19 kg (41.89 lb) (2.5 inch hard drive systems)

23.2 kg (51.15 lb) (3.5 inch hard drive systems)

 

Processor specifications   (Back to top)(Technical specification top)

This section provides processor specifications required for your hardware.

Processor specifications
TypeSpecification
Two Intel Xeon processorEP E5-2600 v3 and v4 product family

 

Expansion bus specifications   (Back to top)(Technical specification top)

This section provides expansion bus specifications for storage, including bus type, expansion cards, and expansion slots.

Expansion bus specifications
Expansion BusSpecification
Bus typePCI Express Generation 3
Expansion CardsFor a list of supported expansion cards, refer to the Owner's Manual at Dell.com/xcseriesmanuals.
Expansion slots using riser card

Riser 1

(Slot 1) One low profile, low profile x8 link

(Slot 2) One low profile, low profile x8 link

(Slot 3) One low profile, low profile x8 link

Riser 2

(Slot 4) One full-height, full-length x16 link

NOTE: To use slots 1 through 4, both the processors must be installed.

(Slot 5) One full-height, full-length x8 link

Riser 3

(Slot 6) One full-height, full-length x8 link

 

Power specifications  (Back to top)(Technical specification top)

This section provides power specifications for your hardware, including wattage, heat dissipation, and voltage.

NOTE: This system is also designed to connect to IT power systems with a phase to phase voltage not exceeding 230 V.

Power Specifications
TypeSpecification
AC power suply unit (PSU)

Wattage

495 W, 750 W, or 1100 W

Heat dissipation

NOTE: Heat dissipation is calculated on the basis of power rating of PSU.

  • 1908 BTU/hr maximum (495 W PSU)
  • 2891 BTU/hr maximum (750 W PSU)
  • 2843 BTU/hr maximum (750 W Titanium PSU)
  • 4100 BTU/hr maximum (1100 W PSU)
  • 4416 BTU/hr maximum (DC 1100 W PSU)
  • 2891 BTU/hr maximum (750 W mixed mode PSU)

Voltage

NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.

  • 100–240 V AC, auto ranging, 50/60 Hz
  • 200–240 V AC, auto ranging, 50/60 Hz, for 750 W Titanium PSU

 

Memory specifications (Back to top)(Technical specification top)

This section provides memory specifications for your hardware, including architecture, memory module sockets, and memory module capacities.

Memory Specifications
MemorySpecification
Architecture
  • 1866, 2133, and 2400 MT/s DIMMs
  • Support for Advanced ECC or memory-optimized operation
Memory module socketsTwenty-four 288-pin
Memory module capacities

LRDIMM

64 GB

RDIMM

16 GB or 32 GB

Maximum RAM

 

Up to 1.5 TB with a dual processor
Minimum RAM

 

64 GB with a dual processor

 

Hard drive specification (Back to top)(Technical specification top)

This section provides hard drive specifications for your hardware.

Hard drive specification
TypeSpecification
Twelve hard-drive systemsUp to twelve 3.5- inch drives
Twenty-four hard-drive systemsUp to twenty-four 2.5- inch drives

 

 

Connector specifications (Back to top)(Technical specification top)

This section provides connectors specifications for your hardware, including rear, front, and internal connectors.

Connector specifications
TypeSpecification
Rear

NIC

Two 1 Gbps plus two 10 Gbps

Serial

9-pin, DTE, 16550-compatible

USB

Two 4-pin, USB 3.0-compliant

Video

15-pin VGA

External vFlash card

One flash memory card slot with iDRAC8 Enterprise card

NOTE: The card slot is available for use only if the iDRAC8 Enterprise license is installed on your system.

Front

USB

One 4-pin, USB 2.0-compliant

One USB management port or iDRAC Direct

Video

15-pin VGA

Internal

USB

One 4-pin, USB 3.0-compliant

Internal Dual SD Module (IDSDM)

Two flash memory card slots with one internal SD card.

 

Video specifications (Back to top)(Technical specification top)

This section provides video specifications for storage, including type, and memory.

Video specifications
TypeSpecification
Video typeMatrox G200eR2

Video memory

16 MB

 

 

Environmental specifications (Back to top)(Technical specification top)

This section provides environmental specifications for storage, including temperature, relative humidity, maximum vibrations, particulate contamination, gaseous contamination, and expanded operating temperature.

NOTE: For more information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.

Environmental specifications
TypeSpecification
Temperature

Storage

–40°C to 65°C (–40°F to 149°F)

Continuous operation (for altitude less than 950 m or 3117 ft)

10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.

Maximum temperature gradient (operating and storage)

20°C/h (36°F/h)
Relative humidity

Storage

5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.

Operating

10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.
Maximum vibration

Storage

1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).

Operating

0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Maximum shock

Storage

Six consecutively run shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Operating

Six consecutively run shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Maximum altitude

Operating

3,048 m (10,000 ft)

Storage

12,000 m (39,370 ft)
Operating altitude de-rating

Up to 35°C (95°F)

Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).

35°C to 40°C (95°F to 104°F)

Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
Particulate contamination
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Remediation of environmental conditions is the responsibility of the customer.

Air filtration

Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

Note:

  • Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
  • Air entering the data center must have MERV11 or MERV13 filtration.

Conductive dust

Air must be free of conductive dust, zinc whiskers, or other conductive particles.

NOTE: Applies to data center and non-data center environments.

Corrosive dust

    • Air must be free of corrosive dust.
    • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.

NOTE: Applies to data center and non-data center environments.

Gaseous contamination
Note: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Copper coupon corrosion rate<300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver coupon corrosion rate<200 Å/month as defined by AHSRAE TC9.9.
Expanded operating temperature
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
Continuous operation
  • 5°C to 40°C at 5% to 85% RH with 29°C dew point.

NOTE: Outside the standard operating temperature (10°C to 35°C), the system can operate continuously down to 5°C or as high as 40°C.

  • For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours–5°C to 45°C at 5% to 90% RH with 29°C dew point.

Documentation matrix (Back to top)

 

The documentation matrix provides information about the documents that you use to configure and deploy the Dell EMC web-scale hyperconverged appliance solution.

Dell EMC documentationNutanix documentation 

WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included with this document or as a separate document.


Make sure that you read through any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the OS, system management software, system updates, and system components that you purchased with your system.

NOTE: URLs such as Dell.com/support or Dell.com/support/home, are not active, because you must type the URL from your location to access your specific language.


For the full name of an abbreviation or acronym used in this document, see the Glossary at Dell.com/support/home.

NOTE: Always read the updates on Dell.com/support/home because they often supersede information in other documents.

NOTE: While upgrading your system, Dell EMC recommends that you download and install the latest BIOS, driver, and systems management firmware on your system from Dell.com/support/home.

 

Dell EMC documentation (Back to top)

Dell EMC documentation is either included with your shipment or available at the Dell EMC website at Dell.com/xcseriesmanuals.

Dell EMC documentation for:

  • Dell iDRAC is available at Dell.com/idracmanuals.
  • Dell OpenManage Essentials is available at Dell.com/openmanagemanuals.

To access Dell EMC documetation:

  1. In the Dell EMC Support page, scroll down to General Support, and then click Servers, Storage & Networking.
  2. Click Engineered Solutions, click Manuals , and select the documentation you require.
Dell EMC reference documentation
To learn about...Refer to...
Setup instructions of your system, including the technical specificationsGetting Started Guide

Hardware details for your system

Owner's Manual

How to install your system in to a rackDell Rack Install Guide
How to deploy and set up this solutionSolutions Guide
Setting up and using Dell iDRAC8Dell iDRAC8 Quick Start Guide
Using OpenManage Essentials to monitor, perform updates, view hardware, and view inventory on your systemDell OpenManage Essentials User's Guide

Nutanix documentation (Back to top)

Nutanix documentation is found using the Nutanix portal found at https://portal.nutanix.com/#/page/docs. You must have user credentials to log in.

The required Nutanix documentation is found using various filters. Use the tables below to locate Nutanix documentation using specific filters.

 

Documentation filtered by AOS 4.7 ALL
To learn about...Acropolis base (NOS) 4.7 document name
Set up instructions for environments with special requirements and restrictions.Acropolis Advanced Setup Guide
Comprehensive references for Controller Virtual Machine (CVM) utilities, nCLI commands, and Nutanix PowerShell cmdletAcropolis Command Reference
Instructions and reference for administering the Nutanix solution software outside the Nutanix Prism UI (such as cluster start/stop, manual upgrade, changing passwords, reconfiguring IP addresses, and troubleshooting tools).Acropolis Advanced Administration Guide
Managing Nutanix Acropolis AHV hosts that run Nutanix solution software.Acropolis Hypervisor Administration Guide
Managing VMware ESXi hosts that run Nutanix solution software, including VMware vCenter requirements.vSphere Administration Guide for Acropolis (using vSphere Client)
Managing Hyper-V hosts that run the Nutanix solution software, including domain requirements.Hyper-V Administration for Acropolis
Comprehensive references for the Nutanix REST API.Acropolis API Reference

Distributed VM management services for Nutanix nodes with Acropolis hypervisor (AHV).

Acropolis App Mobility Fabric Guide

Instructions for manually upgrading AOS.

Acropolis Upgrade Guide

Nutanix support of containers through Acropolis Container Services.

Acropolis Container Services Guide

 

Documentation Filtered by: Foundation 3.4 All
To learn about...Foundation 3.4 document name
Set up instructions for your solution.Field Installation Guide

 

 

Documentation Filtered by: AHV 4.7 All
To learn about...AHV 4.7 document name
Software instructions for hardware components that are not functioning.Acropolis Hypervisor Administration Guide

 

Documentation Filtered by: Platform 4.7 Dell XC Series
To learn about...Dell XC Series 4.7 Platform document name
Software instructions for hardware components that are not functioning.Hardware Replacement Documentation

 

Documentation Filtered by: Prism 4.7 All
To learn about...Prism 4.7 document name
Comprehensive instructions and references for the Nutanix UI, including overview information.Prism Web Console Guide
Monitoring multiple Nutanix cluster through web console. 

 

Contacting Dell EMC    (Back to top)

Dell EMC provides several online and telephone-based support and service options. If you do not have an active internet connection, you can find contact information about your purchase invoice, packing slip, bill, or Dell EMC product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell EMC for sales, technical assistance, or customer-service issues:

  1. Go to Dell.com/support.
  2. Select your country from the drop-down menu on the lower right corner of the page.
  3. For customized support:
    • Enter your system Service Tag in the Enter your Service Tag text box.
    • Click Submit.
    • The support page that lists the various support categories is displayed.
  4. For general support:
    • Select your product category.
    • Select your product segment.
    • Select your product. The support page that lists the various support categories is displayed.
  5. For contact details of Dell EMC Global Technical Support:
    • Click Global Technical Support.
    • The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell EMC Global Technical Support team.

 

Quick Resource Locator 

Use the Quick Resource Locator (QRL) to get immediate access to Dell EMC XC730xd solution information. This information provides access to reference documentation, a link to the Dell EMC support page, and links to hardware-specific QRL pages, which include how-to videos. You can access this information by visiting www.dell.com/QRL or by using your smartphone or tablet and scanning the QR code below. You can also click the image below to go directly to the Dell EMC XC730xd QRL location.

(Back to top)

The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.

Use, copying, and distribution of any software described in this publication requires an applicable software license.

Copyright © 2017 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA. [3/2/2017]

Rev. A08


Viewing all articles
Browse latest Browse all 486

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>